Select Page
Two stage reducing station

 A two stage reduction will provide a more stable outlet pressure even with rapidly decaying inlet pressure. Although all SAB pressure reducer inserts are pressure equalized, the inlet pressure has an impact on the outlet pressure. In order to ensure a very stable outlet pressure a first stage pressure reducer will keep the inlet pressure of the second stage within small margins.The stations are usually equipped with inlet and outlet valves, bypass valve, safety valve, pressure gauges, filter and dome pressure reducer.

Specifications
Nominal width
DN6 to DN32
Rated pressure
up to PN 260 bar
Operating temperature
-30 to +80°C
Operating medium
Compressed air and neutral gases
Inlet pressure
250 bar
Installation position
any
Connections
Threaded connections
Filter mesh
25 µm
Functional test
Pressure reducer (including flow measurement)
Body
20967
Internal parts
2.0967 / 2.0958 / 1.4401
Seals
NBR / PA6.6
Inserts and drives

SAB’s pressure reducing stations are 100% custom made according to the specifications. They can be equipped with any SAB standard cartridge valve to suit the functions needed. See: SUMMARY